• Specifications

    Stand-alone system for acquiring data facility-wide.

    Learn More
    Slide 1
  • Accessories

    Supports 2-way RS-232 communication.

    Learn More
    Slide 2
  • Downloads

    View and download the user manual.

    Learn More
    Slide 3

EDAS-1025


EDAS-1000E Series Ethernet Data Acquisition Systems are stand-alone data acquisition systems that connect to and communicate over Ethernet (IEEE 802.310Base-T) Local Area Networks(LANs). They use the open systems environment of Ethernet and Transmission Control Protocol/Internet Protocol (TCP/IP, a standard networking protocol that provides communication across interconnected networks). These features enable you to integrate acquired data with your facility-wide or world-wide network, making the data available for use by other networked resources, or for further processing by personal or company software.

The EDAS-1025 Serial EDAS systems can allow any RS-232 device, including PLC’s, controllers, instruments, scales, gauges, smart sensors, machines, printers, terminals and scanners, to communicate with computers located anywhere on an Ethernet network. Each EDAS-1025 Serial EDAS provides 2 or 4 RS-232 serial ports. Use this system to allow any RS-232 device, including PLC’s, controllers, instruments, scales, gauges, smart sensors, machines, printers, terminals and scanners, to communicate with computers located anywhere on an Ethernet network. Monitor and Control all types of RS-232 Devices remotely, at any distance, via your existing network. Provides full 2-way communication with each device, from one or more computers – even simultaneously.

Specifications

Serial Ports

  • RS-232: 2 or 4 ports
  • DE-9 connector
  • ASCII, binary communication
  • Supply voltage (3k ohm load) ±6V TX, RTS active

Network Interface

  • Ethernet 10Base-T
  • RJ45 connector
  • Buffer RAM: 4kB
  • EEPROM: 1-24 bits
  • Controller: SMC91C94

Reset Controller

  • Type: MAX809 (or equivalent)
  • 4.4V threshold voltage
  • Range (-40° to +85° C*): 4.25V to 4.5V/140msec to 560msec
  • Reset active time-out period: 240msec

Power

  • Voltage range (AC or DC): 15 to 28 VAC, 20 to 40 VDC
  • OEM (board only) versions (DC): 5VDC
  • Current Requirements
    • 24VAC, no load/1A load: 125mA typical
    • 24VAC: 250mA typical
  • TTL-compatible output levels
  • Output current:
    • Port 0 (source/sink): 15mA/24mA
    • Port 1 (source/sink): 15mA/64mA

Physical

  • Base material: aluminum
  • Cover material: vinyl-clad steel
  • Bezel material: nickel-coated molded ABS plastic
  • Size: 5.125″ D x 7.70″ W x 1.70″ H (13.0 cm D x 19.56 cm W x 4.32 cm H)
  • OEM (board only) version size: 4.50″ D x 7.00″ W x 1.10″ H (11.43 cm D x 17.78 cm W x 2.79 cm H)
  • 0° to 50° C** operating temperature range
  • *The on-board power supply circuit can supply up to 1A @ 5VDC to termination panels through the 50-pin I/O connectors
  • **All specifications are typical at 25° C unless otherwise noted

Back to Top

Accessories

EDAS-1018A-1

EDAS-1018A-1

Operator interface cable, for use with TM2500 microterminals. RS-232, DE-9 male to DE-9 female, 3 meters

EDAS-1024A-1

EDAS-1024A-1

Industrial EDAS enclosure

LPP002

LPP002

24VAC power supply (90-120VAC input)

LPP003

LPP003

24VAC power supply (90-120VAC input)

LPA015

LPA015

Data Transfer Cable, RS-232, DE-9 (AT) and DB-25 (XT)

EDAS-1028A-1

EDAS-1005A-1

DIN-rail mounting kit for EDAS-1001E and EDAS-1002E Ethernet data acquisition systems. Includes aluminum strap and mounting screws.

EDAS-1028A-1

EDAS-1028A-1

Rack-mount kit, 19-inch, for EDAS-1001E, EDAS-1002E and EDAS-1031E systems. Includes 1U-size rack-mount and overlays for installation of up to 3 EDAS units.

Downloads

EDAS 1025E Manual

User Manual for the EDAS-1025E terminal.